Realize online double conversion
Microprocessor control ensures high reliability
Input power factor correction function
Output power factor can reach 0.8
Wide AC input range (110V~300V)
Efficient frequency conversion mode
Compatible with generator input
Supports rich interfaces such as SNMP, RS485/232
Easy operation and control through the display, and comprehensive display and monitoring of UPS status
Model | CT00111TL | CT00211TL | CT00311TL | CT00611TL | CT00611TL | CT01011TL | CT01011TL |
Capacity | 1000VA/900W | 2000VA/1800W | 3000VA/2700W | 6000VA/5400W | 6000VA/5400W | 10000VA/9000W | 10000VA/9000W |
Phase | Single Phase Input, Single Phase Output | Single Phase Input, Single Phase Output | Single Phase Input, Single Phase Output | Single Phase Input, Single Phase Output | Single Phase Input, Single Phase Output | Single Phase Input, Single Phase Output | Single Phase Input, Single Phase Output |
Input Voltage Range | 110-300VAC@50% load; 160-300VAC@100% load | 110-300VAC@50% load; 160-300VAC@100% load | 110-300VAC@50% load; 160-300VAC@100% load | 110-300VAC@50% load; 176-300VAC@100% load | 110-300VAC@50% load; 176-300VAC@100% load | 110-300VAC@50% load; 176-300VAC@100% load | 110-300VAC@50% load; 176-300VAC@100% load |
Frequency Range | 40-70Hz | 40-70Hz | 40-70Hz | 46Hz-54Hz or 56Hz-64Hz | 46Hz-54Hz or 56Hz-64Hz | 46Hz-54Hz or 56Hz-64Hz | 46Hz-54Hz or 56Hz-64Hz |
Power Factor | ≥0.99@100% load | ≥0.99@100% load | ≥0.99@100% load | ≥0.99@100% load | ≥0.99@100% load | ≥0.99@100% load | ≥0.99@100% load |
Output Voltage Range | 200*/208*/220/230/240VAC | 200*/208*/220/230/240VAC | 200*/208*/220/230/240VAC | 208**/220/230/240VAC | 208**/220/230/240VAC | 208**/220/230/240VAC | 208**/220/230/240VAC |
Voltage Regulation | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
Frequency Range (Synchronization Range) | 47-53Hz or 57-63Hz | 47-53Hz or 57-63Hz | 47-53Hz or 57-63Hz | 46-54Hz or 56-64Hz | 46-54Hz or 56-64Hz | 46-54Hz or 56-64Hz | 46-54Hz or 56-64Hz |
Overload (Utility Mode) | 105%-110%: 10 minutes; 110%-130%: 1 minute; >130%: 3 seconds | 105%-110%: 10 minutes; 110%-130%: 1 minute; >130%: 3 seconds | 105%-110%: 10 minutes; 110%-130%: 1 minute; >130%: 3 seconds | 100%-110%: 30 minutes; 110%-130%: 5 minutes; >130%: 10 seconds | 100%-110%: 30 minutes; 110%-130%: 5 minutes; >130%: 10 seconds | 100%-110%: 30 minutes; 110%-130%: 5 minutes; >130%: 10 seconds | 100%-110%: 30 minutes; 110%-130%: 5 minutes; >130%: 10 seconds |
Overload (Battery Mode) | 105%-110%: 10 minutes; 110%-130%: 1 minute; >130%: 3 seconds | 105%-110%: 10 minutes; 110%-130%: 1 minute; >130%: 3 seconds | 105%-110%: 10 minutes; 110%-130%: 1 minute; >130%: 3 seconds | 100%-110%: 3 minutes; 110%-130%: 30 seconds; >130%: 10 seconds | 100%-110%: 3 minutes; 110%-130%: 30 seconds; >130%: 10 seconds | 100%-110%: 3 minutes; 110%-130%: 30 seconds; >130%: 10 seconds | 100%-110%: 3 minutes; 110%-130%: 30 seconds; >130%: 10 seconds |
Harmonic Distortion | ≤3% (Linear Load); ≤6% (Non-linear Load) | ≤3% (Linear Load); ≤6% (Non-linear Load) | ≤3% (Linear Load); ≤6% (Non-linear Load) | ≤3% (Linear Load); ≤5% (Non-linear Load) | ≤3% (Linear Load); ≤5% (Non-linear Load) | ≤3% (Linear Load); ≤5% (Non-linear Load) | ≤3% (Linear Load); ≤5% (Non-linear Load) |
Transfer Time (Utility to Battery) | 0ms | 0ms | 0ms | 0ms | 0ms | 0ms | 0ms |
Transfer Time (Inverter to Bypass) | 4ms (Standard Conditions) | 4ms (Standard Conditions) | 4ms (Standard Conditions) | 0ms | 0ms | 0ms | 0ms |
Efficiency (Utility Mode) | 88% | 89% | 90% | 92% | 92% | 93% | 93% |
Efficiency (Battery Mode) | 83% | 87% | 88% | 90% | 90% | 91% | 91% |
Battery (Standard Unit) | 12V/9Ah | 12V/9Ah | 12V/9Ah | 12V/7Ah or 12V/9Ah | 12V/7Ah or 12V/9Ah | 12V/7Ah or 12V/9Ah | 12V/7Ah or 12V/9Ah |
Battery Quantity (Standard Unit) | 2 | 4 | 6 | 16 | 20 | 16 | 20 |
Long Life Unit | Battery Model | Varies by Application | Varies by Application | Varies by Application | Varies by Application | Varies by Application | Varies by Application |
Battery Quantity (Long Life Unit) | 2, 3, 4, 6, 8, 16-20 | 2, 3, 4, 6, 8, 16-20 | 2, 3, 4, 6, 8, 16-20 | 2, 3, 4, 6, 8, 16-20 | 2, 3, 4, 6, 8, 16-20 | 2, 3, 4, 6, 8, 16-20 | 2, 3, 4, 6, 8, 16-20 |
Dimensions (Standard Unit) | Depth x Width x Height 282 x 145 x 220 mm | Depth x Width x Height 282 x 145 x 220 mm | Depth x Width x Height 397 x 145 x 220 mm | Depth x Width x Height 421 x 190 x 318 mm | Depth x Width x Height 369 x 190 x 688 mm | - | 442 x 190 x 688 mm |
Net Weight (Standard Unit) | 9.8 kg | 9.8 kg | 17 kg | 27.6 kg | 51 kg | 62 kg | 55 kg |
Dimensions (Long Life Unit) | Depth x Width x Height 282 x 145 x 220 mm | Depth x Width x Height 282 x 145 x 220 mm | Depth x Width x Height 397 x 145 x 220 mm | Depth x Width x Height 397 x 145 x 220 mm | Depth x Width x Height 369 x 190 x 318 mm | 369 x 190 x 318 mm | 442 x 190 x 318 mm |
Net Weight (Long Life Unit) | 4.1 kg | 4.1 kg | 6.8 kg | 7.4 kg | 12 kg | 12 kg | 15 kg |
Operating Environment | Temperature and Humidity 20-90%RH@0-40°C (Non-condensing) 0-95%RH@0-50°C (Non-condensing) |