Availability: | |
---|---|
Quantity: | |
Pure double conversion technology
Automatic rotation of LCD screen
(only for 10~30k models) DSP technology ensures high performance
Output power factor 1.0
With power factor correction
50Hz/60Hz inverter mode with energy-saving working mode (ECO) Emergency shutdown function (EPO)
Support generator
Support two-way input
Three-stage charging design to optimize battery performance Adjustable battery quantity for long-term operation
Support shared battery pack
Optional isolation transformer
Optional parallel operation
SNMP+USB+RS232 multiple communications
Power supply walk-in function
Model | CT01033RL | CT01533RL | CT02033RL | CT03033RL | CT04033RL | CT06033RL |
Capacity | 10kVA/10kW | 15kVA/15kW | 20kVA/20kW | 30kVA/30kW | 40kVA/40kW | 60kVA/60kW |
Phase | Three Phase Input/Three Phase Output | Three Phase Input/Three Phase Output | Three Phase Input/Three Phase Output | Three Phase Input/Three Phase Output | Three Phase Input/Three Phase Output | Three Phase Input/Three Phase Output |
Input Voltage Range | 110-300VAC@50% load; 176-276VAC@100% load | 110-300VAC@50% load; 176-276VAC@100% load | 110-300VAC@50% load; 176-276VAC@100% load | 110-300VAC@50% load; 176-276VAC@100% load | 110-300VAC@50% load; 176-276VAC@100% load | 110-300VAC@50% load; 176-276VAC@100% load |
Frequency Range | 46-54Hz or 56-64Hz | 46-54Hz or 56-64Hz | 46-54Hz or 56-64Hz | 46-54Hz or 56-64Hz | 46-54Hz or 56-64Hz | 46-54Hz or 56-64Hz |
Power Factor | ≥0.99@100% load | ≥0.99@100% load | ≥0.99@100% load | ≥0.99@100% load | ≥0.99@100% load | ≥0.99@100% load |
Output Voltage Range | 3 × 360V/380V/400V/415VAC (3Ph+N) | 3 × 360V/380V/400V/415VAC (3Ph+N) | 3 × 360V/380V/400V/415VAC (3Ph+N) | 3 × 360V/380V/400V/415VAC (3Ph+N) | 3 × 360V/380V/400V/415VAC (3Ph+N) | 3 × 360V/380V/400V/415VAC (3Ph+N) |
Voltage Regulation | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
Frequency Tolerance (Synchronization Range) | 46-54Hz or 56-64Hz | 46-54Hz or 56-64Hz | 46-54Hz or 56-64Hz | 46-54Hz or 56-64Hz | 46-54Hz or 56-64Hz | 46-54Hz or 56-64Hz |
Overload Capacity (Utility Mode) | 100%-110%: 60 minutes; 110%-125%: 10 minutes; 125%-150%: 1 minute; >150%: Immediate | 100%-110%: 60 minutes; 110%-125%: 10 minutes; 125%-150%: 1 minute; >150%: Immediate | 100%-110%: 60 minutes; 110%-125%: 10 minutes; 125%-150%: 1 minute; >150%: Immediate | 100%-110%: 60 minutes; 110%-125%: 10 minutes; 125%-150%: 1 minute; >150%: Immediate | 100%-110%: 60 minutes; 110%-125%: 10 minutes; 125%-150%: 1 minute; >150%: Immediate | 100%-110%: 60 minutes; 110%-125%: 10 minutes; 125%-150%: 1 minute; >150%: Immediate |
Harmonic Distortion | ≤2% (Linear Load); ≤5% (Non-linear Load) | ≤2% (Linear Load); ≤5% (Non-linear Load) | ≤2% (Linear Load); ≤5% (Non-linear Load) | ≤2% (Linear Load); ≤5% (Non-linear Load) | ≤2% (Linear Load); ≤5% (Non-linear Load) | ≤2% (Linear Load); ≤5% (Non-linear Load) |
Transfer Time (Utility to Battery) | 0ms | 0ms | 0ms | 0ms | 0ms | 0ms |
Transfer Time (Inverter to Bypass) | 0ms (Phase Failure, <4ms Interruption) | 0ms (Phase Failure, <4ms Interruption) | 0ms (Phase Failure, <4ms Interruption) | 0ms (Phase Failure, <4ms Interruption) | 0ms (Phase Failure, <4ms Interruption) | 0ms (Phase Failure, <4ms Interruption) |
Transfer Time (Inverter to ECO) | <10ms | <10ms | <10ms | <10ms | <10ms | <10ms |
Efficiency (Utility Mode) | 95.50% | 95.50% | 95.50% | 95.50% | 95.50% | 95.50% |
Efficiency (Battery Mode) | 94.50% | 94.50% | 94.50% | 94.50% | 94.50% | 94.50% |
Battery Model | Varies by Application | Varies by Application | Varies by Application | Varies by Application | Varies by Application | Varies by Application |
Number of Batteries | 20 | 20 | 20 | 20 | 32~40 | 32~40 |
Dimensions (Depth x Width x Height mm) | 680 x 438 x 133 | 797 x 438 x 176 | 797 x 438 x 176 | 797 x 438 x 176 | 1065 x 600 x 2010 | 1100 x 600 x 2010 |
Net Weight (kg) | 26 | 28 | 29 | 34 | 45 | 58 |
Operating Environment | Temperature: 0-40°C (Non-condensing) | Humidity: 0-95%RH @ 0-40°C (Non-condensing) | Temperature: 0-40°C (Non-condensing) | Humidity: 0-95%RH @ 0-40°C (Non-condensing) | Temperature: 0-40°C (Non-condensing) | Humidity: 0-95%RH @ 0-40°C (Non-condensing) |
Altitude | <1000m | <1000m | <1000m |