Availability: | |
---|---|
Quantity: | |
3U single power module with power up to 50kW
Single 42U cabinet, capacity up to 400kVA
Supports N+1 or N+X parallel redundancy of power system
Modular design reduces MTTR (mean time to maintenance)
High scalability
Built-in maintenance bypass switch, easy maintenance, uninterrupted output
High-efficiency double conversion online UPS
Flexible battery configuration and adjustable charging current
High overload capacity
Power walk-in function
Model | CT300 | CT400 | CT500 |
Capacity | 300kVA/300kW | 400kVA/400kW | 500kVA/500kW |
Power Module Capacity | 50kVA/50kW | 50kVA/50kW | 50kVA/50kW |
Number of Power Modules Installed | 6 | 8 | 10 |
Phase | Three-phase input, three-phase output | Three-phase input, three-phase output | Three-phase input, three-phase output |
Input Voltage Range | 208~304VAC@70% load; 305~478VAC@100% load | 208~304VAC@70% load; 305~478VAC@100% load | 208~304VAC@70% load; 305~478VAC@100% load |
Frequency Range | 40~70Hz | 40~70Hz | 40~70Hz |
Power Factor | ≥0.99@100% load | ≥0.99@100% load | ≥0.99@100% load |
Output Voltage Range | 3 x 380/400/415VAC (3Ph+N) | 3 x 380/400/415VAC (3Ph+N) | 3 x 380/400/415VAC (3Ph+N) |
Voltage Regulation | ±1% (balanced load); ±2% (unbalanced load) | ±1% (balanced load); ±2% (unbalanced load) | ±1% (balanced load); ±2% (unbalanced load) |
Frequency Range (Synchronization Range) | 46~54Hz or 56~64Hz | 46~54Hz or 56~64Hz | 46~54Hz or 56~64Hz |
Overload (Utility Mode) | 105%-110%: 60 minutes; 110%-125%: 10 minutes; 125%-150%: 1 minute; >150%: 200ms | 105%-110%: 60 minutes; 110%-125%: 10 minutes; 125%-150%: 1 minute; >150%: 200ms | 105%-110%: 60 minutes; 110%-125%: 10 minutes; 125%-150%: 1 minute; >150%: 200ms |
Overload (Battery Mode) | 105%-110%: 60 minutes; 110%-125%: 10 minutes; 125%-150%: 1 minute; >150%: 200ms | 105%-110%: 60 minutes; 110%-125%: 10 minutes; 125%-150%: 1 minute; >150%: 200ms | 105%-110%: 60 minutes; 110%-125%: 10 minutes; 125%-150%: 1 minute; >150%: 200ms |
Harmonic Distortion | <2% (Linear Load); <4% (Non-linear Load) | <2% (Linear Load); <4% (Non-linear Load) | <2% (Linear Load); <4% (Non-linear Load) |
Transfer Time (Inverter to Bypass) | ≤20ms | ≤20ms | ≤20ms |
Efficiency | 95.50% | 95.50% | 95.50% |
Battery Model | Varies by Application | Varies by Application | Varies by Application |
Number of Batteries | 32-40 | 32-40 | 32-40 |
Dimensions (Depth x Width x Height mm) | 1065 x 600 x 2010 | 1100 x 600 x 2010 | 1065 x 1000 x 2000 |
Net Weight (kg) | 287 | 308 | 420 |
Operating Environment | Humidity: 0~95%RH@0~40°C (Non-condensing) | Altitude: <1000m | Noise: <73dB@1 meter |
Control Management | Support for Windows series, Linux, and MAC | Support for SNMP management and network browser power management |